Minimum and Maximum Reinforcing Steel Ratios According to ACI 318-02
Title: Minimum and Maximum Reinforcing Steel Ratios According to ACI 318-02
Author(s): Noel Everard
Publication: Concrete International
Volume: 25
Issue: 2
Date: February 1, 2003
ABSTRACT
Discusses minimum and maximum steel ratio changes to the 2002 ACI building code from a designer’s perspective. Minimum and maximum steel ratios for walls, columns, and flexural members are explained.